SEC-1215UL 12V 15 Amp 3-Bank Battery Charger
What’s Included?: Only Charger (DC Cord & Connector Sold Separately)
Voltages: 12V
Charging Current: 15A
Battery Types: Lead-Acid (Flooded/AGM/Gel)
Dimensions In. (mm): 8.6 x 8.4 x 3.3 (218 x 214 x 83)
Weight lb. (kg): 4.8 (2.2)
Special Features: Charge 3 Banks of Batteries at Once
- Product SKU: SC1000528
Contact us for availability
Couldn't load pickup availability
We supply direct to distributor pickup warehouses across Canada, connecting you to a reliable inventory of power products. Proceed to checkout for full warehouse details and pickup processing.
Picking Up Your Order
Products are available for same-day pickup unless otherwise noted. You’ll receive a confirmation email— typically within the hour— once your order is ready. Once you receive this email, you can pick up your order anytime Monday to Friday between 8 AM and 5 PM.
Our warehouses feature drive-up bay doors and dedicated staff to ensure fast, safe, and professional pickups, no matter the size of your order.
Canada Wide Locations
Our pickup locations are in London, Mississauga, Kingston, Ottawa, Sudbury, Thunder Bay, Montreal, Sherbrooke, Lévis (Quebec City), Moncton, Vancouver (Delta), Kelowna, Prince George, Fort McMurray, Grand Prairie, Edmonton, Calgary, Saskatoon, Regina, Winnipeg and Halifax.
Contact us to place your order and schedule your pickup, or simply use our easy online checkout process.
We offer various shipping methods to accommodate your needs, including free business delivery, third-party shipping and specialty carrier shipping to remote areas.
Products available for pickup only on our website are available for business delivery and third-party shipping. To receive a shipping quote, contact a Voltloop representative via our toll-free number or email.
Free Business Delivery
We supply free business delivery within a 100-kilometer radius of our facilities located in all major cities in Canada, including London, Mississauga, Kingston, Ottawa, Sudbury, Thunder Bay, Montreal, Sherbrooke, Lévis (Quebec City), Moncton, Vancouver (Delta), Kelowna, Fort McMurray, Grand Prairie, Edmonton, Calgary, Saskatoon, Regina, Winnipeg and Halifax. Contact us to setup an account and qualify today.
Returns, Refunds and Warranties
Voltloop offers a 30-day return policy on select items, as well as full refunds for orders cancelled prior to processing. In addition, our products are backed by industry-leading manufacturer warranties, which are noted on each product page.
No hidden core fees, plus we give you money back to recycle your old battery. All of our pickup locations are registered recycling depots, so when you pick up your new battery, we can recycle your old one and give you cash back.
Battery Exchange
Battery scrap values depend on current market prices and vary based on size and chemistry. Prices are determined on location and are not subtracted from the original sale price.
Batteries must be a minimum size to qualify for our money back program, with the approximate minimum size being a 35 lb. automotive battery. Please note that we do not remove or replace batteries in vehicles or equipment, and batteries must be removed before you proceed to our locations.
Samlex SEC-1215UL 12V 15 Amp 3-Bank Battery Charger
This advanced fully automatic three-stage 15 Amp battery charger is ideal for charging all types of 12 Volt lead-acid batteries ( Flooded / Absorbed Glass Mat (AGM) / Gel Cell) from a 120 VAC, 50/60 Hz (default) or 230 VAC, 50/60 Hz (internal jumper setting) AC source. User selectable ( by DIP Switch) for 2 or 3 stage, rapid and safe charging of stand-alone and loaded Lead Acid Batteries. The unit can also be used as a DC Power Supply. Features include overload and short-circuit protection. The unit allows charging of up-to 3 separate battery banks.
- Charge 3 banks of batteries at once – no isolator necessary
- High efficiency
- Commercial Grade
- Lightweight
- Quiet operation
- Industry Proven Design – 1000s of units in operation
- User Selectable ( by DIP Switch) for 2 or 3 stage, rapid and safe charging of stand-alone and loaded Lead Acid Batteries
- 120 VAC, 50/60 HZ (default) or 230 VAC, 50/60 Hz (internal jumper setting)
- Voltage meter display – Ammeter and LED power status
- For all types of Lead Acid batteries
- Charge with a battery load or stand alone
- Use as a power supply or DC UPS
- UPC: Universal Protection Circuit – short circuit, overload, reverse battery polarity
| INPUT & OUTPUT | PHYSICAL SPECIFICATIONS | ||
| Nominal Input Voltage & Frequency | 120 VAC, 50 / 60 Hz (Default) ; 230 VAC, 50 / 60Hz (Internal jumper setting) | LED Display | RED LED: Output is available |
| AC Input Current | (i) At 120 VAC: 3.3A, (ii) At 230 VAC: 1.8A | Analogue Meter | Ammeter: 0 to 15A |
| AC Input Connection | Attached Power Cord: 6 ft length ; 3 x 18AWG wire size ; NEMA5-15P Plug | Type of Cooling | Convection cooled (No fan) |
| Charging Current | 15A | L x W x H | 218 x 214 x 83 mm / 8.6 x 8.4 x 3.3 in |
| Charging Stages |
3 Stages (DIP Switch setting - Default): Bulk, Absorption and Float 2 Stages (DIP Switch setting): Bulk and Float |
Weight | 4.8lb / 2.2kg |
| Charging Voltages |
Absorption: 14.4 VDC (Default) ; 14.0 VDC (DIP Switch setting) ; Disable (DIP Switch setting) Float: 13.5 VDC |
||
| No. of Charging Banks | 3 | ||
| Output Connections | Tubular Hole with Set Screw ; Hole Diameter: 4 mm / 0.16 in |
| FUSES | PROTECTION | ||
| Internal AC Input Side Fuse (120vac) | 4A, 250V; Size 5mm x 20mm; Time Delay Type Mfr.: Littelfuse 0218004 or equivalent | Output Short Circuit | No output voltage, Auto reset on removal or short |
| Internal AC Input Side Fuse (230vac) | 2A, 250V; Size 5mm x 20mm; Time Delay Type Mfr.: Littelfuse 0218002 or equivalent | Input Overload | 4A input side fuse will blow (120 VAC input) |
| Internal DC Output Side Fuse | 32V, 20A; Automotive Blade Type; Fast Acting Mfr.: Littelfuse 0287020 or equivalent | Output Overload | Electronic current limit at 15A |
| Reverse Polarity on Output Side | 20A output side fuse will blow |
| ENVIRONEMNT | COMPLIANCE | ||
| Operating Temperature Range | -20°C to +40°C / -4°F to +104 | Safety | Conforms to UL STD. 1564 |
| Storage Temperature | -30°C to +70°C / -22°F to +158°F | Certified to CSA STD. C22.2 No. 107.2 | |
| Relative Humidity | Up to 90%, non condensing | Emi | FCC Part 15(B), Class B |
| Operating Condition | Indoor, Ventilated, Cool and Dust Free |