RB100-LT 12V LiFePO4 Lithium Deep Cycle Battery Group 31 | 100 AH
Voltage: 12V
AH @ 20hr: 100
Energy (Wh): 1280
R/C @ 25A: 240 min.
Depth of Discharge (DOD): 13000 Cycles @ 50% DOD
Terminal Type: M8
MBC #: LITH12-100-LT
Dimensions In. (mm): 13.0 x 6.8 x 8.8 (329 x 172 x 223)
Weight Lb. (kg): 27.9 (12.64)
- Product SKU: RB1000461
*No Hidden Core Fees
Contact us for availability
Couldn't load pickup availability
We supply direct to distributor pickup warehouses across Canada, connecting you to a reliable inventory of power products. Proceed to checkout for full warehouse details and pickup processing.
Picking Up Your Order
Products are available for same-day pickup unless otherwise noted. You’ll receive a confirmation email— typically within the hour— once your order is ready. Once you receive this email, you can pick up your order anytime Monday to Friday between 8 AM and 5 PM.
Our warehouses feature drive-up bay doors and dedicated staff to ensure fast, safe, and professional pickups, no matter the size of your order.
Canada Wide Locations
Our pickup locations are in London, Mississauga, Kingston, Ottawa, Sudbury, Thunder Bay, Montreal, Sherbrooke, Lévis (Quebec City), Moncton, Vancouver (Delta), Kelowna, Prince George, Fort McMurray, Grand Prairie, Edmonton, Calgary, Saskatoon, Regina, Winnipeg and Halifax.
Contact us to place your order and schedule your pickup, or simply use our easy online checkout process.
We offer various shipping methods to accommodate your needs, including free business delivery, third-party shipping and specialty carrier shipping to remote areas.
Products available for pickup only on our website are available for business delivery and third-party shipping. To receive a shipping quote, contact a Voltloop representative via our toll-free number or email.
Free Business Delivery
We supply free business delivery within a 100-kilometer radius of our facilities located in all major cities in Canada, including London, Mississauga, Kingston, Ottawa, Sudbury, Thunder Bay, Montreal, Sherbrooke, Lévis (Quebec City), Moncton, Vancouver (Delta), Kelowna, Fort McMurray, Grand Prairie, Edmonton, Calgary, Saskatoon, Regina, Winnipeg and Halifax. Contact us to setup an account and qualify today.
Returns, Refunds and Warranties
Voltloop offers a 30-day return policy on select items, as well as full refunds for orders cancelled prior to processing. In addition, our products are backed by industry-leading manufacturer warranties, which are noted on each product page.
No hidden core fees, plus we give you money back to recycle your old battery. All of our pickup locations are registered recycling depots, so when you pick up your new battery, we can recycle your old one and give you cash back.
Battery Exchange
Battery scrap values depend on current market prices and vary based on size and chemistry. Prices are determined on location and are not subtracted from the original sale price.
Batteries must be a minimum size to qualify for our money back program, with the approximate minimum size being a 35 lb. automotive battery. Please note that we do not remove or replace batteries in vehicles or equipment, and batteries must be removed before you proceed to our locations.
Relion RB100-LT 12V LiFePO4 Lithium Deep Cycle Battery
The RB100-LT is a 12V 100Ah lithium battery and is part of RELiON’s Low-Temperature Series. This lithium iron phosphate battery is specially designed for cold weather performance. RELiON’s LT Series batteries can safely charge at temperatures down to -20°C (-4°F) using a standard charger. The system features proprietary technology which draws power from the charger itself, requiring no additional components.
The entire process of heating and charging with the LT Series is completely seamless. Simply plug the battery into the regular lithium charger and the internal heating and monitoring system takes care of the rest. Because it takes time to heat the cells, the charging process in below-freezing temperatures could take a little longer.
The Low-Temperature Series battery has the same size and performance as other RELiON batteries but can safely charge when temperatures drop as low as -20°C using a standard charger. The RB100-LT is an ideal choice for use in RVs, off-grid solar, electric vehicles, and in any application where charging in colder temperatures is necessary.
|
ELECTRICAL SPECIFICATIONS |
MECHANICAL SPECIFICATIONS |
||
|
Nominal Voltage |
12.8 V |
Dimensions (L x W x H) |
12.95 x 6.77 x 8.9” 329 x 172 x 223 mm |
|
Nominal Capacity |
100 Ah |
Weight |
27.9 lbs (12.64 kg) |
|
Capacity @ 25A |
240 min |
Terminal Type |
M8 x 1.25 |
|
Energy |
1280 Wh |
Terminal Torque |
80 - 100 in-lbs (9 - 11 N-m) |
|
Resistance |
≤30 mΩ @ 50% SOC |
Case Material |
ABS |
|
Efficiency |
99% |
Enclosure Protection |
IP66 |
|
Self Discharge |
<3% per Month |
Cell Type - Chemistry |
Cylindrical - LiFePO4 |
|
Maximum Modules in Series |
1 (Single-Use) |
|
|
|
DISCHARGE SPECIFICATIONS |
CHARGE SPECIFICATIONS |
||
|
Maximum Continuous Discharge Current |
100 A |
Recommended Charge Current |
5 A - 50 A |
|
Peak Discharge Current |
200 A (7.5 s ±2.5 s) |
Maximum Charge Current |
100 A |
|
BMS Discharge Current Cut-Off |
280 A ±50 A (32 ±10 ms) |
Recommended Charge Voltage |
14.2 V - 14.6 V |
|
Recommended Low Voltage Disconnect |
11 V |
BMS Charge Voltage Cut-Off |
15.4 V (3.85 ±0.025 vpc) (1000 ±200 ms) |
|
BMS Discharge Voltage Cut-Off |
9.2 V (2.3 ±0.08 vpc) (4.7 ±1 s) |
Reconnect Voltage |
14.6 V (3.65 ±0.05 vpc) |
|
Reconnect Voltage |
10 V (2.5 ±0.1 vpc) |
Balancing Voltage |
14.4 V (3.6 ±0.025 vpc) |
|
Short Circuit Protection |
200-600 μs |
Recommended Charge Current |
5 A - 50 A |
|
|
|
Maximum Charge Current |
100 A |
|
TEMPERATURE SPECIFICATIONS |
HEATING ELEMENT SPECIFICATIONS |
||
|
Discharge Temperature |
-4 to 140 ºF (-20 to 60 ºC) |
Heating Temperature Range |
-4 to 41 ºF (-20 to 5 ºC) |
|
Charge Temperature |
-4 to 113 ºF (-20 to 45 ºC) |
Heating Time |
Approximately 1 hr @ 10 A |
|
Storage Temperature |
23 to 95 ºF (-5 to 35 ºC) |
|
|
|
BMS High Temperature Cut-Off - Discharge |
185 ºF (85 ºC) |
|
|
|
BMS High Temperature Cut-Off - Charge |
140 ºF (60 ºC) |
|
|
|
Reconnect Temperature |
122 ºF (50 ºC) |
|
|
|
COMPLAINCE SPECIFICATIONS |
|
|
Certifications |
CE (battery) |
|
|
UL1642 & IEC62133 (cells) |
|
Shipping Classification |
UN 3480, CLASS 9 |
Manufacturer Limited Warranty 3 Years Replacement or Repair Warranty with 10 Year Total Warranty.