RB100-HP 12V LiFePO4 Lithium Deep Cycle Group 31 | 100 AH
Voltage: 12V
Group Size: 31
AH @ 20hr: 100
Energy (Wh): 1280
R/C @ 25A: 240 min.
Depth of Discharge (DOD): 13000 Cycles @ 50% DOD
Terminal Type: M8
MBC #: LITH12-100-HP
Dimensions In. (mm): 13.0 x 6.8 x 8.8 (329 x 172 x 223)
Weight Lb. (kg): 29.8 (13.5)
Our RB100-HP is a dual-purpose 12V, 100 Ah lithium battery. Our HP Series batteries are high performing dual purpose deep cycle batteries that can handle both starting and cycling. The RB100-HP has increased peak amps over our standard batteries. This increase in peak amps can be used to start motors, electric start generators and other high amp draw devices. After starting, the battery can double as a house battery providing power for peripherals, accessories and other onboard needs.
RELiON’s HP Series batteries are a perfect compromise between the unique demands of starting service and deep cycling, low amp draw service. The RB100-HP is a powerhouse that is also versatile and compact enough for use in many marine applications including bass boats and shallow bottom boats.
The RB100-HP features installation flexibility and no maintenance over the life of the battery. It maintains consistent power and is equipped with an M8 terminal type and a built-in battery management system (BMS).
Our RB100-HP is a dual-purpose 12V, 100 Ah lithium battery. Our HP Series batteries are high performing dual purpose deep cycle batteries that can handle both starting and cycling. The RB100-HP has increased peak amps over our standard batteries. This increase in peak amps can be used to start motors, electric start generators and other high amp draw devices. After starting, the battery can double as a house battery providing power for peripherals, accessories and other onboard needs.
RELiON’s HP Series batteries are a perfect compromise between the unique demands of starting service and deep cycling, low amp draw service. The RB100-HP is a powerhouse that is also versatile and compact enough for use in many marine applications including bass boats and shallow bottom boats.
The RB100-HP features installation flexibility and no maintenance over the life of the battery. It maintains consistent power and is equipped with an M8 terminal type and a built-in battery management system (BMS).
ELECTRICAL SPECIFICATIONS |
MECHANICAL SPECIFICATIONS |
|
|
|||
Nominal Voltage |
12.8 V |
Dimensions (L x W x H) |
13.0 x 6.8 x 8.8” 329 x 172 x 223 mm |
|||
Nominal Capacity |
100 Ah |
Weight |
29.8 lbs (13.5 kg) |
|||
Capacity @ 25A |
240 min |
Terminal Type |
M8 x 1.25 |
|||
Energy |
1280 Wh |
Terminal Torque |
80 - 100 in-lbs (9 - 11 N-m) |
|||
Resistance |
≤30 mΩ @ 50% SOC |
Case Material |
ABS |
|||
Efficiency |
99% |
Enclosure Protection |
IP66 |
|||
Self Discharge |
<3% per Month |
Cell Type - Chemistry |
Cylindrical - LiFePO4 |
|||
Maximum Modules in Series |
1 (Single Use) |
|
|
DISCHARGE SPECIFICATIONS |
CHARGE SPECIFICATIONS |
||
Maximum Continuous Discharge Current |
100 A |
Recommended Charge Current |
5 A - 50 A |
Peak Discharge Current |
800 A (2 s) |
Maximum Charge Current |
100 A |
BMS Discharge Current Cut-Off |
1000 A ±100 A (2.2 ±1 ms) |
Charge Current 32°F to 14°F (0 to -10°C) |
≤0.1 C |
Recommended Low Voltage Disconnect |
11 V |
Charge Current 14°F to -4°F (-10 to -20°C) |
≤0.05 C |
BMS Discharge Voltage Cut-Off |
9.2 V (2.3 ±0.08 vpc) (4.2 ±0.5 s) |
Recommended Charge Voltage |
14.2 V - 14.6 V |
Reconnect Voltage |
10 V (2.5 ±0.1 vpc) |
BMS Charge Voltage Cut-Off |
15.4 V (3.85 ±0.025 vpc) |
Short Circuit Protection |
200-600 µs |
|
(1 ±0.2 s) |
|
|
Reconnect Voltage |
14.6 V (3.65 ±0.05 vpc) |
|
|
Balancing Voltage |
14.4 V (3.6 ±0.025 vpc) |
TEMPERATURE SPECIFICATIONS |
COMPLIANCE SPECIFICATIONS |
||
Discharge Temperature |
-4 to 140 ºF (-20 to 60 ºC) |
Certifications |
CE (battery) |
Charge Temperature* |
-4 to 113 ºF (-20 to 45 ºC) |
|
UL1642 & IEC62133 (cells |
Storage Temperature |
23 to 95 ºF (-5 to 35 ºC) |
Shipping Classification |
UN 3480, CLASS 9 |
BMS High Temperature Cut-Off |
176 ºF (80 ºC) |
|
|
Reconnect Temperature |
122 ºF (50 ºC) |
|
|
*Refer to charge currents below 32°F (0°C) |
|
|
|
Manufacturer Limited Warranty 3 Years Replacement or Repair Warranty with 10 Year Total Warranty.